MASTER LIGHT/BUZZER CONNECTION DIAGRAM
A MASTER WARNING INDICATOR SHOULD ALWAYS BE USED. WHEN THE LEVELING SYSTEM HAS
STRAIGHT-ACTING JACKS A WARNING BUZZER MUST BE USED.
NOTE: BY SUPPLYING IGNITION POWER TO THE WARNING BUZZER AND LIGHT, AND "ACC" POWER TO THE
CONTROL BOX, THE SYSTEM MAY BE OPERATED IN ACCESSORY WITHOUT THE BUZZER SOUNDING.
THE NEGATIVE SIGNAL FOR THE WARNING INDICATORS MUST ALWAYS COME FROM THE CONTROL BOX.
5-15 AMP FUSE
JACK
DOWN
LIGHT
7699
6111
WARN LIGHT
CONTROL
MP85.804R
MANUAL LEVELING SYSTEMS
625 SERIES LEVELING SYSTEM
CONNECT THIS END TO
+12 VOLT IGNITION "ON" POWER
PIGTAIL W/DIODE
AND IN-LINE
FUSE HOLDER - 6121
_
6111
7699
BUZZER
CONTROL
PIGTAIL PROVIDED - 7699
BUZZER
SEE CONTROL BOX
CONNECTION
INFORMATION
7699
MP85.304R