Download Print this page

HWH 625 SERIES Operator's Manual page 32

Computer-controlled leveling system and spacemaker room extension systems
Hide thumbs Also See for 625 SERIES:

Advertisement

ROOM EXTENSION MANIFOLD CONNECTIONS
B
5053
5153
6810
12 PIN
GREEN
ELECTRICAL CONNECTION DIAGRAM
TOP VIEW
1E
2E
3E
4E
GEN
5E
SLIDE
1E - ROOM 1 CYL EXTEND - ROOM EXTEND
1R - ROOM 1 CYL RETRACT - ROOM RETRACT
2E - ROOM 2 CYL EXTEND - ROOM EXTEND
A
2R - ROOM 2 CYL RETRACT - ROOM RETRACT
3E - ROOM 3 CYL EXTEND - ROOM RETRACT
3R - ROOM 3 CYL RETRACT - ROOM EXTEND
4E - ROOM 4 CYL EXTEND - ROOM EXTEND
4R - ROOM 4 CYL RETRACT - ROOM RETRACT
5E - GEN CYL EXTEND - SLIDE EXTEND
5R - GEN CYL RETRACT - SLIDE RETRACT
TO HWH GROUND STUD
6245
ROOM 4
1R
2R
3R
4R
GEN
5R
SLIDE
ON PUMP
ROOM EXTENSION
MANIFOLD
CYLINDER EXTEND
VALVE
HWH GROUND
STUD
NOTE: LEVELING SYSTEM
MANIFOLD NOT SHOWN.
B
A
6245
PUMP
RELAY
TO PUMP
MOTOR
MASTER
RELAY
CYLINDER
RETRACT
VALVE
MP85.189E
12MAY04

Advertisement