APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 9 of 9)
ADDRESS
FLEXANALOG NAME
14189
PTP–IRIG-B Delta
14256
CT1 COMP I1 Mag
14258
CT1 COMP I2 Mag
14260
CT2 COMP I1 Mag
14262
CT2 COMP I2 Mag
24447
Active Setting Group
32768
Tracking Frequency
39168
FlexElement 1 Value
39170
FlexElement 2 Value
39172
FlexElement 3 Value
39174
FlexElement 4 Value
39176
FlexElement 5 Value
39178
FlexElement 6 Value
39180
FlexElement 7 Value
39182
FlexElement 8 Value
41132
VTFF 1 V0 3rd Harmonic
41134
VTFF 2 V0 3rd Harmonic
45584
GOOSE Analog In 1
45586
GOOSE Analog In 2
45588
GOOSE Analog In 3
45590
GOOSE Analog In 4
45592
GOOSE Analog In 5
45594
GOOSE Analog In 6
45596
GOOSE Analog In 7
45598
GOOSE Analog In 8
45600
GOOSE Analog In 9
45602
GOOSE Analog In 10
45604
GOOSE Analog In 11
45606
GOOSE Analog In 12
45608
GOOSE Analog In 13
45610
GOOSE Analog In 14
45612
GOOSE Analog In 15
45614
GOOSE Analog In 16
FlexInteger items are also viewable in a web browser. In the browser, enter the IP address of the UR, access the Device
Information Menu option, then the FlexInteger Parameter Listing option.
Table A–2: FLEXINTEGER DATA ITEMS
ADDRESS
FLEXINTEGER NAME
9968
GOOSE UInt Input 1
9970
GOOSE UInt Input 2
9972
GOOSE UInt Input 3
9974
GOOSE UInt Input 4
9976
GOOSE UInt Input 5
9978
GOOSE UInt Input 6
9980
GOOSE UInt Input 7
9982
GOOSE UInt Input 8
GE Multilin
UNITS
DESCRIPTION
ns
PTP time minus IRIG-B time
Amps
CT bank1 compensated I1 current
Amps
CT bank1 compensated I2 current
Amps
CT bank2 compensated I1 current
Amps
CT bank2 compensated I2 current
---
Current setting group
Hz
Tracking frequency
---
FlexElement 1 actual value
---
FlexElement 2 actual value
---
FlexElement 3 actual value
---
FlexElement 4 actual value
---
FlexElement 5 actual value
---
FlexElement 6 actual value
---
FlexElement 7 actual value
---
FlexElement 8 actual value
Volts
V0 3rd Harmonic 1
Volts
V0 3rd Harmonic 2
---
IEC 61850 GOOSE analog input 1
---
IEC 61850 GOOSE analog input 2
---
IEC 61850 GOOSE analog input 3
---
IEC 61850 GOOSE analog input 4
---
IEC 61850 GOOSE analog input 5
---
IEC 61850 GOOSE analog input 6
---
IEC 61850 GOOSE analog input 7
---
IEC 61850 GOOSE analog input 8
---
IEC 61850 GOOSE analog input 9
---
IEC 61850 GOOSE analog input 10
---
IEC 61850 GOOSE analog input 11
---
IEC 61850 GOOSE analog input 12
---
IEC 61850 GOOSE analog input 13
---
IEC 61850 GOOSE analog input 14
---
IEC 61850 GOOSE analog input 15
---
IEC 61850 GOOSE analog input 16
UNITS
DESCRIPTION
---
IEC61850 GOOSE UInteger input 1
---
IEC61850 GOOSE UInteger input 2
---
IEC61850 GOOSE UInteger input 3
---
IEC61850 GOOSE UInteger input 4
---
IEC61850 GOOSE UInteger input 5
---
IEC61850 GOOSE UInteger input 6
---
IEC61850 GOOSE UInteger input 7
---
IEC61850 GOOSE UInteger input 8