GE L60 Instruction Manual page 613

Line phase comparison system ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 45 of 59)
ADDR
REGISTER NAME
B402
IEC 61850 GGIO1 Indication FlexLogic operands (128
items)
IEC 61850 Configurable GOOSE Transmission (Read/Write Setting) (8 modules)
B5A0
IEC 61850 Configurable GOOSE Function (GoEna)
B5A1
IEC 61850 Configurable GOOSE ID
B5C2
Configurable GOOSE Destination MAC Address
B5C5
IEC 61850 Configurable GOOSE VLAN Transmit Priority
B5C6
IEC 61850 Configurable GOOSE VLAN ID
B5C7
IEC 61850 Configurable GOOSE ETYPE APPID
B5C8
IEC 61850 Configurable GOOSE ConfRev (Configuration
Revision)
B5CA
IEC 61850 Configurable GOOSE Retransmission Curve
B5CB
Configurable GOOSE dataset items for transmission
(64 items)
B60B
...Repeated for module number 2
B676
...Repeated for module number 3
B6E1
...Repeated for module number 4
B74C
...Repeated for module number 5
B7B7
...Repeated for module number 6
B822
...Repeated for module number 7
B88D
...Repeated for module number 8
IEC 61850 Configurable GOOSE Reception (Read/Write Setting) (16 modules)
B900
Configurable GOOSE Dataset Items for Reception
(32 items)
B920
...Repeated for module number 2
B940
...Repeated for module number 3
B960
...Repeated for module number 4
B980
...Repeated for module number 5
B9A0
...Repeated for module number 6
B9C0
...Repeated for module number 7
B9E0
...Repeated for module number 8
BA00
...Repeated for module number 9
BA20
...Repeated for module number 10
BA40
...Repeated for module number 11
BA60
...Repeated for module number 12
BA80
...Repeated for module number 13
BAA0
...Repeated for module number 14
BAC0
...Repeated for module number 15
BAE0
...Repeated for module number 16
Contact Inputs (Read/Write Setting) (96 modules)
BB00
Contact Input 1 Name
BB06
Contact Input 1 Events
BB07
Contact Input 1 Debounce Time
BB08
...Repeated for Contact Input 2
BB10
...Repeated for Contact Input 3
BB18
...Repeated for Contact Input 4
BB20
...Repeated for Contact Input 5
BB28
...Repeated for Contact Input 6
BB30
...Repeated for Contact Input 7
BB38
...Repeated for Contact Input 8
BB40
...Repeated for Contact Input 9
BB48
...Repeated for Contact Input 10
BB50
...Repeated for Contact Input 11
BB58
...Repeated for Contact Input 12
BB60
...Repeated for Contact Input 13
GE Multilin
RANGE
0 to 4294967295
0 to 1
---
---
0 to 7
0 to 4095
0 to 16383
1 to 4294967295
0 to 3
0 to 1008
0 to 197
---
0 to 1
0 to 16
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F102
---
---
F209
"GOOSEOut_x_"
---
---
F072
---
1
F001
---
1
F001
---
1
F001
---
1
F003
---
1
F611
---
1
F616
---
1
F233
---
---
F205
---
1
F102
ms
0.5
F001
DEFAULT
0
1 (Enabled)
B
0
4
0
0
1
3 (Relaxed)
0 (None)
0 (None)
"Cont Ip 1"
0 (Disabled)
20
B-53