3 SPECIFICATIONS

3.7 Remote Registers

3.7.1 Assignment of remote registers

3 - 18
The AJ65SBT-CLB has the remote registers to make data communication with the
master module.
This section explains the assignment and data structure of the remote registers of the
AJ65SBT-CLB.
The following tables indicate the assignment of the remote registers.
(1) RWw
Address
RWwn
RWwn 1
RWwn 2
RWwn 3
to
RWwn F
n: Address assigned to the master station in station number setting.
(2) RWr
(a) When 2 stations are occupied
Address
RWrn
RWrn 1
RWrn 2
RWrn 3
RWrn 4
RWrn 5
to
RWrn 7
n: Address assigned to the master station in station number setting.
(b) When 4 stations are occupied
Address
RWrn
RWrn 1
RWrn 2
RWrn 3
RWrn 4
RWrn 5
RWrn 6
RWrn 7
RWrn 8
to
RWrn F
n: Address assigned to the master station in station number setting.
Remote Register Definition
Last station number setting
Data link stop/restart instructions
Error status flag clear
Use prohibited
Remote Register Definition
Data of operating statuses
Data of faulty station : Station number 1 to 12
Remote I/O error data :Station number 1 to 12
Data of remote station connection
Setting data
Use prohibited
Remote Register Definition
Data of operating states
Data of faulty station : Station number 1 to 28
Remote I/O error data :Station number 1 to 28
Data of remote station connection
Setting data
Use prohibited
MELSEC-A
Initial value
Reference
0
Sec. 3.7.2
0
Sec. 3.7.3
0
Sec. 3.7.4
Reference
Sec. 3.7.5
Sec. 3.7.6
Sec. 3.7.7
Sec. 3.7.8
Sec. 3.7.9
Reference
Sec. 3.7.5
Sec. 3.7.6
Sec. 3.7.7
Sec. 3.7.8
Sec. 3.7.9
3 - 18