Performance Specifications - Mitsubishi Melsec-A AJ65SBT User Manual

Cc-link - cc-link/lt bridge module
Table of Contents

Advertisement

3 SPECIFICATIONS

3.2 Performance Specifications

The following table provides the performance specifications of the AJ65SBT-CLB.
Item
Station type
CC-Link Version
2 stations
Number of
4 stations
occupied
stations
8 stations
(4 occupied stations
modules)
AJ65SBT-CLB connection position
External connection system
Maximum number of link points
Number in parentheses assumes
use of the same I/O addresses
Number of link points per station
Number in parentheses assumes
use of the same I/O addresses
Transmission speed
Communication system
Transmission path format
Error control system
Number of connected modules
Remote station number
AJ65SBT-CLB connection position Connected at the end of the trunk line
RAS functions
Connection cable 1
Module mounting screw
Module mounting direction
Voltage
24V DC power
Current consumption
supply 2
Start-time current
Level of protection
Weight
1 Performance of the CC-Link/LT cannot be guaranteed for use of cables other than the dedicated flat cables, VCTF
cables and high flexible cables.
2 Supplied by the dedicated power supply or power supply adaptor of CC-Link/LT.
3 For VCTF cable specifications, see Table 3.3.
4 Use the dedicated flat cables and high flexible cables accredited by the CC-Link Partner Association. (Refer to Section
2.4.)
3 - 2
3.2 Performance specifications
Table
Remote device station
Ver.1.10
64 points each for RX and RY (16 points are used in the system)
8 points each for RWr and RWw
128 points each for RX and RY (16 points are used in the system)
16 points each for RWr and RWw
256 points each for RX and RY (32 points are used in the system)
2
32 points each for RWr and RWw
No restrictions
One-touch connector for communication [transmission circuit] (5-pin,
insulation displacement type connector plug is sold separately)
<Sold separately> Online connector for communication: A6CON-LJ5P
4-point mode
4 points
(8 points)
2.5Mbps/625kbps/156kbps
BITR system (Broadcastpolling
T-branch system
CRC
56 modules
1 to 56
Network diagnostics, internal loopback diagnostics, slave station
separation, automatic return to system
Dedicated flat cable (0.75mm
flexible cable 4
M4
0.7mm
Tightening torque range 78 to 108N cm
DIN rail can also be used for mounting.
Can be mounted in any of six orientations.
(No restrictions on mounting directions)
24V DC externally supplied (20.4V DC to 26.4V DC, ripples within 5%)
0.075A (When 24V DC)
0.165A (When 24V DC)
IP2X
0.09kg
Specifications
8-point mode
224 points (448 points)
8 points
(16 points)
Interval Timed Response)
2
X4) 4, VCTF cable 3, high
16mm or more screw
MELSEC-A
3
16-point mode
16 points
(32 points)
3 - 2

Advertisement

Table of Contents
loading

Table of Contents