Connection Of The Cc-Link Dedicated Cables - Mitsubishi Melsec-A AJ65SBT User Manual

Cc-link - cc-link/lt bridge module
Table of Contents

Advertisement

4 PROCEDURE UP TO DATA LINK

4.6.1 Connection of the CC-Link dedicated cables

[CC-Link dedicated cable wiring diagram]
Terminating
Master module
resistor
(Blue)
DA
(White)
DB
(Yellow)
DG
SLD
FG
Ver.1.10 Compatible CC-Link dedicated cable (FANC-110SBH,CS-110,FA-CBL200PSBH)
4 - 19
Connect the CC-Link dedicated cable between the AJ65SBT-CLB and master module
as shown below.
Online connector
for communication
(Blue)
NC
(White)
(Yellow)
NC
SLD
NC
(Blue)
(White)
NC
(Yellow)
SLD
NC
POINT
For this module, use the Ver. 1.10-compatible CC-Link dedicated cable (FANC-
110SBH,CS-110,FA-CBL200PSBH).You cannot use the Ver. 1.10-compatible
CC-Link dedicated cables, CC-Link dedicated cables or CC-Link dedicated, high-
performance cables of other than the above models.
The shield wire of the CC-Link dedicated cable should be connected to "SLD" in
each module, and both ends should be grounded through "FG".
"SLD" and "FG" are connected inside the module.
One-touch connector plug
for communication
CONA
1
1
DA
2
2
DB
3
3
DG
4
4
NC
5
5
SLD
CONB
1
1
DA
2
2
DB
3
3
DG
4
4
NC
5
5
SLD
MELSEC-A
Online connector for
communication
One-touch connector plug
with terminating resistor
A6CON-TR11
Online connector
for communication
CONA
(Blue)
1
1
(White)
2
2
(Yellow)
3
3
4
4
SLD
5
5
CONB
1
1
2
2
3
3
4
4
5
Terminating
5
resistor
(A6CON-TR11)
DA
DB
DG
NC
SLD
DA
DB
DG
NC
SLD
FG
4 - 19