Flowmeter Sensor - ABB FEX300 Original Instruction

Electromagnetic flowmeter
Hide thumbs Also See for FEX300:
Table of Contents

Advertisement

8.2.2

Flowmeter sensor

Fig. 19
Replace the flowmeter sensor as follows:
1. Switch off the supply power and wait at least 20 minutes before the next step.
2. Open the cover safety device (4) and housing cover (1).
3. Disconnect the signal cable (if necessary, remove the sealing compound).
4. Install the new sensor according to the installation instructions.
5. Complete the electrical connection according to the connection diagram.
6. Close the housing cover (1) and lock the cover by unscrewing the screw (3).
SM/FEX300/FEX500/FM/CSA-EN
1
FEX300, FEX500
Maintenance
2
3
G00698-01
G00698
EN - 39