ABB FEX300 Original Instruction page 28

Electromagnetic flowmeter
Hide thumbs Also See for FEX300:
Table of Contents

Advertisement

Ex relevant specifications for operation in Div. 1
Table 2: Fluid temperature (Ex data) for ProcessMaster models FEP315, FEP515
(- 40 °C)
Not thermally
insulated
Gas
NT
T1
HT
NT
T2
HT
NT
T3
HT
NT
T4
HT
NT
T5
HT
NT
T6
HT
NT
T1
HT
NT
T2
HT
NT
T3
HT
NT
T4
HT
NT
T5
HT
NT
T6
HT
1)
Low-temperature version (option)
NT: standard sensor design, T
HT: high-temperature sensor design, T
Not thermally insulated: The flowmeter sensor is not surrounded by pipe insulation material.
Thermally insulated: The flowmeter sensor is surrounded by pipe insulation material.
Note
The standard version includes explosion protection for gases and dust. Explosion protection for dust is only available for devices featuring a
transmitter in a dual-compartment housing.
If the installation location for the device is classified as a potentially explosive area for gases and dust, the temperature data
in the "Gas & dust" columns in the table must be taken into consideration.
If the installation location for the device is classified as a potentially explosive area for gases only, the temperature data in
the "Gas" column in the table must be taken into consideration.
26 - EN
1)
- 20 °C ... + 40 °C
Thermally
insulated
Gas &
Gas &
Gas
dust
dust
130 °C
180 °C
130 °C
180 °C
130 °C
180 °C
120 °C
120 °C
85 °C
85 °C
70 °C
70 °C
130 °C
180 °C
130 °C
180 °C
130 °C
180 °C
125 °C
125 °C
90 °C
90 °C
75 °C
75 °C
maximum 130 °C (266 °F),
medium
maximum 180 °C (356 °F)
medium
Ambient temperature
(- 40 °C)
1)
- 20 °C ... + 50 °C
Not thermally
Thermally
insulated
insulated
Gas &
Gas
Gas
dust
FEX300, FEX500
(- 40 °C)
1)
- 20 °C ... + 60 °C
Not thermally
insulated
Gas &
Gas &
Gas
dust
dust
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
70 °C
30 °C
85 °C
20 °C
70 °C
30 °C
70 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
120 °C
20 °C
90 °C
30 °C
90 °C
20 °C
75 °C
30 °C
75 °C
20 °C
SM/FEX300/FEX500/FM/CSA-EN
Thermally
insulated
Gas &
Gas
dust
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
85 °C
20 °C
70 °C
40 °C
70 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
120 °C
20 °C
80 °C
40 °C
90 °C
20 °C
75 °C
40 °C
75 °C
20 °C

Hide quick links:

Advertisement

Table of Contents
loading