6. Insert the new gobo in the holder. Insert the retaining ring, making sure
the tab fits in the goboholder slot.
7. Replace the retaining spring with the narrow end in, against the ring.
Make sure the outside end of the spring is held firmly in place in its slot
in the goboholder.
8. Slide the tab on the goboholder under the clip on the gobowheel and
make sure that the teeth on the goboholder engage the gobo wheel
correctly.
9. Replace the head cover and be ready for the head to move when you
reapply power.

Lamp replacement

Warning! Wear safety glasses and gloves when handling
lamps.
Allow the fixture to cool for at least 2 hours before handling a
lamp.
To avoid the risk of a discharge lamp exploding in the fixture,
replace the lamp when it reaches its specified lifetime (see
Lamp on page 42).
Install only lamps that are approved by Martin® for this fixture
(see Lamp on page 42).
If a lamp breaks, ventilate the room for 30 minutes, put on nitrile gloves and
remove the pieces . Put the pieces in a sealed plastic bag and take them to
your local waste facilities for specialist recycling. Do not use a vacuum
cleaner to clean up pieces of a broken lamp.
The lamp must be perfectly clean and totally free of oil and grease. Never
touch the lamp with bare hands. If you contaminate the lamp, clean it with
an alcohol wipe and then dry it with a lint-free cloth.
To replace the lamp:
1. Disconnect the fixture from power and allow it to cool for one hour.
2. Remove the lamp cover using a TX10 TORX screwdriver.