To clean the fixture:
1. Disconnect the fixture from power and allow it to cool for at least 15
minutes.
2. Vacuum or gently blow away dust and loose particles from the outside of
the fixture and the air vents with low-pressure compressed air.
3. Clean the LED lenses by wiping gently with a soft, clean lint-free cloth
moistened with a weak detergent solution. Do not rub the surface hard: lift
particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth
or low-pressure compressed air. Remove stuck particles with an
unscented tissue or cotton swab moistened with glass cleaner or distilled
water.
4. Check that the fixture is dry before reapplying power.

Fuse replacement

If the fixture is completely dead, the fixture's primary fuse F1 may have blown
and it may be necessary to install a new fuse. This fuse is located in a
fuseholder next to the Mains OUT socket on the connections panel. (see
Fixture overview on page 11).
To change the fuse:
1. Disconnect the fixture from power and allow it to cool for at least 15
minutes.
2. Use a large flat-bladed screwdriver to unscrew the cap of the fuseholder.
3. Replace the fuse with one of the same type and rating only.
4. Reinstall the fuseholder cap before reapplying power.