11.9

How to Share Route During Route Monitoring

With multiple units (FMD-3xx0, FCR-2xx9, FAR-3xx0) connected, the master unit can
share a monitored route with the units mentioned above
Follow the procedure below to set master and backup units.
Follow the procedure below to enabling the route sharing feature.
1. Open the menu, select [Monitoring] from the [Shared] menu to show the [Setting]
dialog box.
2. Right click the equipment ID of the unit to show the pop-up menu. Select [MAS-
TER], [BACKUP], [SYNC] or [CLEAR] as appropriate.
[MASTER]: Assigns selected unit as the master unit. One unit must be assigned
as the master unit.
[BACKUP]: Assigns the selected unit to share route monitoring. Only one unit can
be assigned to share route monitoring. When route monitoring starts on the mas-
ter, the route and its information are displayed on the backup.
[SYNC]: Selected unit receives and displays the route data output from the mas-
ter, but does not monitor the route displayed on the master.
[CLEAR]: Removes the selected unit from route monitoring sharing.
Note: To restore the original setting for units, click the [Status] column, then select
[Reset].
3. Click the [Save] button to save settings, then click the [Close] button to finish.
ECD001