Anti-tamper and anti-pulling switches
M
A
® J S
– User Guide
ORPHO
CCESS
ERIES
Example 1: Send an alarm ID (62221) in Wiegand, and play sound
warning, in case of intrusion detection.
To send an alarm in Wiegand, the configuration key app/send ID wiegand/
enabled must be set to 1, and the configuration key app/tamper alarm/level
must be set to 2 (alarm and buzzer).
The configuration key app/failure ID/alarm ID must be set to 62221 to link the
intrusion event to this identifier and the configuration key app/failure ID/
enabled must be set to 1.
Example 2: Send an alarm in UDP quietly in case of intrusion detection.
To send an alarm in UDP, the configuration key app/send ID UDP/enabled
must be set to 1.
Then the configuration key app/tamper alarm/level must be set to 1 (quiet
alarm.)