Initial Commissioning - Ahlborn ALMEMO 2490-2 Operating Instructions Manual

Universal measuring instruments
Table of Contents

Advertisement

Output
All data logs, measured values, and programming parameters can be output to
any peripheral equipment. RS232, RS422, USB, and Ethernet interfaces are
available using the appropriate interface cables. Measured data can be output
in list, column, or table format. Files in table format can be processed directly
using any standard spreadsheet software. The print header can be pro-
grammed to refer specifically to your company or to your application.
Networking
®
All ALMEMO
devices can be addressed and can be easily networked by
simply linking them together via network cable or over longer distances via an
internal RS485 interface (option) or RS422 network distributors.
Software
®
Each ALMEMO
age, which can be used to configure the measuring instrument, to program the
sensors, and to read out from the measured value memory. Using the integ-
rated terminal, measuring operations can also be performed online. The WIN-
®
DOWS
software package WIN-Control is provided for the purposes of meas-
ured value acquisition via networked devices, for graphical presentation, and
for more complex data processing.

6. INITIAL COMMISSIONING

1. Connect sensor to socket M0 (1); see 8.
2. Ensure that the power supply is provided via 3 AA batteries or mains adapter;
3. Switch ON by pressing key
4. Select measuring channels by pressing key
values (5e); see 10.1.1.
5. Save the measured value by pressing key
6. Relative measuring with respect to a reference value or sensor adjust-
ment by pressing key
ing and holding down key
7. Differential measurement (2490-2 only), plug 2 sensors of same type into
sockets M0 and M1 and then select measuring point M2; see 10.6
8. Evaluating a measuring operation
Call up maximum / minimum values by pressing keys
To delete max. / min. value(s) press and hold down key
10.2.
9. Programming or data output via interface (not type L)
Connect computer via interface cable to socket A1; see Manual 5.2.
Activate supplied software AMR-Control.
Via 'Setup interface' set the COM port and transmission rate to 9600 bauds.
Program the sensors via 'Program measuring point list'.
Manual is accompanied by the AMR-Control software pack-
ON
CLR
(6); return to normal measured value by press-
CLR
see 10.4.
(6) ; see 7.5.
M▲
MEM
ALMEMO
Functions
(6), read out measured
(6) see 10.3.
MAX
/
MIN
(6)
MAX
or
®
2490
MIN
; s.
13