Siemens SITRANS F Operating Instructions Manual page 68

Communication modules sitrans f m mag 8000 modbus rtu
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Modbus holding registers
A.14 Datalog
Modbus
Data type /
register
Size [bytes]
4:0559
uint8 / 1
4:0560
date / 6
4:0563
float32 / 4
4:0565
float32 / 4
4:0567
uint16 / 2
4:0568
uint8 / 1
4:0569
date / 6
4:0572
float32 / 4
4:0574
float32 / 4
4:0576
uint16 / 2
4:0577
uint8 / 1
4:0578
date / 6
4:0581
float32 / 4
4:0583
float32 / 4
4:0585
uint16/ 2
4:0586
uint8 / 1
4:0587
date / 6
4:0590
float32 / 4
4:0592
float32 / 4
4:0594
uint16 / 2
4:0595
uint8 / 1
4:0596
date / 6
4:0599
float32 / 4
66
Parameter
Description
Log period 7 status
See log period 2
information
Date of log period 8
Date where value for log 8 is
stored
Log period 8 totalized
Log period 8 logged value of
(1)
consumption based on totalizer 1
Log period 8 totalized
Log period 8 logged value of
(2)
consumption based on totalizer 2
Log period 8 fault
See log period 2
status
Log period 8 status
See log period 2
information
Date of log period 9
Date where value for log 9 is
stored
Log period 9 totalized
Log period 9 logged value of
(1)
consumption based on totalizer 1
Log period 9 totalized
Log period 9 logged value of
(2)
consumption based on totalizer 2
Log period 9 fault
See log period 2
status
Log period 9 status
See log period 2
information
Date of log period 10
Date where value for log 10 is
stored
Log period 10 totalized
Log period 10 logged value of
(1)
consumption based on totalizer 1
Log period 10 totalized
Log period 10 logged value of
(2)
consumption based on totalizer 2
Log period 10 fault
See log period 2
status
Log period 10 status
See log period 2
information
Date of log period 12
Date where value for log 1 2 is
stored
Log period 12 totalized
Log period 12 logged value of
(1)
consumption based on totalizer 1
Log period 12 totalized
Log period 12 logged value of
(2)
consumption based on totalizer 2
Log period 12 fault
See log period 2
status
Log period 12 status
See log period 2
information
Date of log period 12
Date where value for log 1 2 is
stored
Log period 12 totalized
Log period 12 logged value of
(1)
consumption based on totalizer 1
Default value
[unit] /
Value range
- [-]
- [-]
- [-]
1)
- [-]
1)
- [-]
- [-]
- [-]
- [-]
1)
- [-]
1)
- [-]
- [-]
- [-]
- [-]
1)
- [-]
1)
- [-]
- [-]
- [-]
- [-]
1)
- [-]
1)
- [-]
- [-]
- [-]
- [-]
1)
MAG 8000 Modbus RTU
Operating Instructions, 04/2016, A5E03409989-AB
Access level
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only

Advertisement

Table of Contents
loading

Table of Contents