Siemens SITRANS F Operating Instructions Manual page 55

Communication modules sitrans f m mag 8000 modbus rtu
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Modbus
Data type /
register
Size [bytes]
4:0306
uint8 / 1
4:0307
date / 6
4:0310
date / 6
4:0313
uint16 / 2
4:0314
uint8 / 1
4:0315
date / 6
4:0318
date / 6
4:0321
uint16 / 2
4:0322
uint8 / 1
4:0323
date / 6
4:0326
date / 6
4:0329
uint16 / 2
4:0330
uint8 / 1
4:0331
date / 6
4:0334
date / 6
4:0337
uint16 / 2
4:0338
uint8 / 1
4:0339
date / 6
4:0342
date / 6
4:0345
uint16 / 2
4:0346
uint8 / 1
4:0347
date / 6
4:0350
date / 6
4:0353
uint16 / 2
4:0354
uint8 / 1
MAG 8000 Modbus RTU
Operating Instructions, 04/2016, A5E03409989-AB
Parameter
Description
Low power fault
Total number of faults
counter
Low power fault ap-
First time the fault appeared
pears
Low power fault dis-
Last time the fault disappeared
appears
Overflow fault hours
Total hours fault active
Overflow fault counter Total number of faults
Overflow fault ap-
First time the fault appeared
pears
Overflow fault disap-
Last time the fault disappeared
pears
Pulse A overload fault
Total hours fault active
hours
Pulse A overload fault
Total number of faults
counter
Pulse A overload fault
First time the fault appeared
appears
Pulse A overload fault
Last time the fault disappeared
disappears
Pulse B overload fault
Total hours fault active
hours
Pulse B overload fault
Total number of faults
counter
Pulse B overload fault
First time the fault appeared
appears
Pulse B overload fault
Last time the fault disappeared
disappears
Consumption fault
Total hours fault active
hours
Consumption fault
Total number of faults
counter
Consumption fault
First time the fault appeared
appears
Consumption fault
Last time the fault disappeared
disappears
Leakage fault hours
Total hours fault active
Leakage fault counter Total number of faults
Leakage fault ap-
First time the fault appeared
pears
Leakage fault disap-
Last time the fault disappeared
pears
Empty pipe fault timer Total hours fault active
Empty pipe fault
Total number of faults
counter
Modbus holding registers
A.9 Error messages
Default value
Access level
[unit] /
Value range
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
- [-]
Read Only
- [-]
Read Only
- [h]
Read Only
- [-]
Read Only
53