REVERSED INLET CONNECTIONS

The Excel is supplied with inlet connections hot left, cold right and bottom outlet.
The Excel B is supplied with inlet connections hot left, cold right and top outlet as
standard. If the hot and cold water supply pipes have been reversed during installation
the following procedure must be performed.
1.1 Isolate the hot and cold water supplies to the shower control.
1.2 Turn the flow knob fully anticlockwise to drain any water.
1.3 Carefully pull off the temperature knob, indicator trim and flow lever. Remove the
shroud.
Note! The red and blue pillars identify the correct hot and cold inlets for the
cartridge.
1.4 Remove the four cartridge retaining screws.
1.5 Pull out the cartridge. Do not remove the metal plate from the cartridge
assembly. Any residual water will drain from the body.
Caution! Take care not to damage the two inlet seals or the large cartridge seal.
1.6 Rotate the cartridge through half a turn (180°) and insert it back into the shower
control body. The blue pillar should now be on the left side of the shower
control. When re-inserting the cartridge, make sure that the large cartridge seal
is first located in the shower control body.
1.7 Fit the four screws that retain the cartridge.
1.8 Refit the shroud.
1.9 Refit the controls. Refer to section: Control Assembly Fitting Instructions.
1.10 Restore the hot and cold water supplies and check for any leaks.