3.4 If installing the shower into a solid wall,
mark an opening sufficient to
accommodate the shower control
approximately 245 mm x 145 mm on
the surface of the wall.
Alternatively, if installing the shower
into a dry-lined wall,
installation template and mark around
the outside edge.
3.5 Mark the route of the supply and outlet
pipes.
3.6 Remove the plaster and brick/block for
the shower control to a depth between
64 and 81 mm from the finished
surface of the wall. The shower body
requires a clearance depth of 58 mm,
with a finished wall surface thickness
between 6 and 23 mm.
Note! The maximum and minimum
depth levels are indicated on the outer
sections of the building-in shroud.
3.7 Remove the plaster and brick/block for
the supply and outlet pipes.
use the
Spirit Level
Bend tabs outwards and place
the spirit level on tabs to level the template
Finished wall
surface
Finished wall surface
23
245 mm
6 mm Minimum Depth
Support
Bracket
58 mm
23 mm
Maximum depth
Installation
Template

Hide quick links: