3.8 Mark the support bracket fixing hole
positions. The support brackets
should be positioned so that the
valve can be fitted level and the
compression fittings can be easily
tightened.
3.9 Drill a 6.0 mm diameter hole at each
of the marked positions and insert the
wall plugs (supplied).
Note! For stud partition installations
alternative fixings may be required.
Alternatively the shower body can
be secured to the rear face of the
wall cavity or to a timber noggin.
3.10 Align the holes in the support brackets
with the holes in the wall and secure
the unit with the two fixing screws
(supplied).
3.11 Remove all three sections of the
building-in shroud. Align the hot and
cold supply and top outlet pipes with
the valve but do not connect to the
valve.
3.12 Remove the support bracket
and valve unit from the wall and
thoroughly flush the hot and cold water
supply pipes.
Note! The supplies must be clean and
free from debris before connecting the
shower control. Failure to do so may
result in product malfunction.
Note! The Excel B is supplied with inlet
connections hot left, cold right and
top outlet as standard. For
installations with reversed hot and cold
refer to section: Reversed inlet
connections.