3.
Key switch
-
Disconnect connector (1) of key switch
-
Turn key "ON"
-
Connect Tester " " and check continuity as
follows:
Terminal (+)
Orange cable (2)
Terminal (-)
Green cable (3)
See "Checking connectors" on page 11
1
COMPLIANT
4.
Check connections
-
Check connections of signalling system
See "Circuit Diagram"
08.06
ISSUE
B
- TROUBLESHOOTING
ELECTRIC SYSTEM TROUBLESHOOTING
Signal System
2
3
SECTION 2
NOT COMPLIANT
Faulty key switch
Replace
NOT COMPLIANT
Resume system's connections
B
CHAPTER
31
PAGE
SECTION 2