4

FUNCTIONAL TEST

This functional test always with door open!
Enter code (1,2,3,4,5,6) and turn handle clockwise towards OPEN position. The bolts should retract
easily and there should be a positive snap action. To lock, turn handle towards LOCKED position. The
bolts should move freely into their locked position (snap action). The lock secures automatically.
Repeat the functional test several times before closing the safe door.
5

DATA SHEET

Mechanics
Opening
Locking
Blocking element
Mounting dimensions
Elektronics
Power supply
Software
Codes
Manager Codes
User Codes
Battery low signal
Manipulation protection
6
Manually
Manually
Motor
Not standard
9V ALKALINE Duracell, Duracell Industrial- or
Energizer battery
2 (6-digit)
1
1
Ja
5 minute lock out after 4 consecutive wrong codes