2
PERFORMANCE SPECIFICATIONS
This chapter describes the performance specifications of the remote head module.
For the specifications of CC-Link IE Field Network, refer to the following.
 User's manual for the master/local module used
Item
Maximum number of link points
per station
Station type
Station number
Network number
Communication speed
Network topology
Communication cable
Maximum station-to-station distance
Number of cascade connections
Number of I/O points
Number of user device points
Number of system device points
Number of module access
device points
Number of refresh data register
points
Label capacity
Memory capacity
Number of storable files
Allowable momentary power failure time
Internal current consumption (5VDC)
External dimensions
Weight
2 PERFORMANCE SPECIFICATIONS
20
RX
RY
RWr
RWw
Input relay (X)
Output relay (Y)
Input (X)
Output (Y)
Link special relay (SB)
Link register (W)
Link special register (SW)
Special relay (SM)
Special register (SD)
Intelligent function module device
(U\G)
Refresh data register (RD)
Device/label memory
Data memory
Device/label memory
Data memory
Height
Width
Depth
Specifications
2K points (2048 points, 256 bytes)
2K points (2048 points, 256 bytes)
1K points (1024 points, 2K bytes)
1K points (1024 points, 2K bytes)
Intelligent device station
1 to 120
1 to 239
1Gbps
Line topology, star topology (coexistence of line topology and star topology is also
possible), and ring topology
Ethernet cable which satisfies 1000BASE-T standard:
Category 5e or higher, straight cable (double shielded, STP)
 User's manual for the master/local module used
100m (conforms to ANSI/TIA/EIA-568-B (Category 5e))
20 levels maximum
4096 points (Number of points accessible to the actual module)
4096 points (Number of points accessible to the actual module)
12288 points (Number of points can be used in the program. Assign X0 to RX0.)
12288 points (Number of points can be used in the program. Assign RY0 to Y0.)
8192 points (SB0000 to SB0FFF are used by the system. SB1000 to SB1FFF can
be used by the user.)
8192 points (Assign 1024 points (W0 to W3FF) from RWw0. Assign 1024 points
(W1000 to W13FF) from RWr0.)
8192 points (SW0000 to SW0FFF are used by the system. SW1000 to SW1FFF
can be used by the user.)
4096 points
4096 points
*2
268435456 points
12288 points
2048 words
256K bytes
2049K bytes
One (A system file is stored.)
*3
256
The time differs depending on the power supply module used. ( MELSEC iQ-R
Module Configuration Manual)
0.75A
106mm (Base unit mounting side: 98mm)
27.8mm
110mm
0.20kg
*1
*1