Table 4: Environmental Conditions

Operating
0°C to +60°C (32°F~140°F) operating temperature (forced cooling).
It is the customer's responsibility to provide sufficient airflow around each of the
components to keep them within allowed temperature range. Please refer to the thermal
simulation report for information about airflow.
10% to 90% relative humidity (non-condensing)
Storage
-20°C~80°C (-4°F~176°F); lower limit of storage temperature is defined by specification
restriction of on-board CR2032 battery.
Board with battery has been verified for storage temperature down to -40 C by Kontron.
Up to 95% relative humidity (non-condensing)
Radiated Emissions
All Peripheral interfaces intended for connection to external equipment are EMI protected.
(EMI)
FCC class B Generic Emission Standard
Safety
IEC 60950-1: 2005, 2nd Edition
UL 60950-1
CSA C22.2 No. 60950-1
Product Category: Information Technology Equipment Including Electrical Business
Equipment. Product Category CCN: NWGQ2, NWGQ8. File number: E147705
Restriction of
All boards in the mITX-SKL family are RoHS compliant
Hazardous
Substances (RoHS)
www.kontron.com
mITX-SKL-S/H110 – Rev. 1.1