Huawei SUN2000-55KTL-HV-D1 User Manual page 81

Sun2000-55ktl; sun2000-60ktl series
Hide thumbs Also See for SUN2000-55KTL-HV-D1:
Table of Contents

Advertisement

SUN2000-(55KTL, 60KTL) Series
User Manual
No.
Parameter
Description
7
Crystalline
This parameter
silicon PV
reduces the DC
compensati
voltage of PV modules
on mode
to the PE by reducing
the impedance of the
SUN2000 input side to
the PE, thereby
effectively reducing
PID effect of PV
modules.
8
Communic
The standards of
ation
certain countries and
interrupt
regions require that
shutdown
the SUN2000 must
shut down after the
communication is
interrupted for a
certain time.
9
Communic
Specifies the duration
ation
for determining
interruptio
communication
n duration
interruption, and is
used for automatic
shutdown for
protection in case of
communication
interruption.
10
Communic
If this parameter is
ation
enabled, the SUN2000
Issue 02 (2017-07-30)
Unit
Default
Value
N/A
Output
disabled
N/A
Disable
min
30
N/A
Enable
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Value Range
Remarks
input power
greatly
decreases.
If PV module
type is set to
CPV 2, the
SUN2000 can
restart quickly in
10 minutes if PV
modules are
shaded and the
input power
greatly
decreases.
Output
This parameter is
disabled
displayed if PV
module type is set
P-type output
to Crystalline
N-type
silicon. Set this
output
parameter to P-type
output for P-type
PV modules and
N-type output for
N-type PV modules.
Disable
If Communication
interrupt
Enable
shutdown is set to
Enable and the
SUN2000
communication has
been interrupted for
a specified time (set
by Communication
interruption
duration), the
SUN2000 will
automatically shut
down.
[1, 120]
N/A
Disable
N/A