Operations Related To The Advanced User; Setting Grid Parameters - Huawei SUN2000-55KTL-HV-D1 User Manual

Sun2000-55ktl; sun2000-60ktl series
Hide thumbs Also See for SUN2000-55KTL-HV-D1:
Table of Contents

Advertisement

SUN2000-(55KTL, 60KTL) Series
User Manual

7.2.1 Operations Related to the Advanced User

Description
If you log in to the app as Advanced User, you can set the grid parameters, protection
parameters, and feature parameters for the SUN2000.

7.2.1.1 Setting Grid Parameters

Procedure
Step 1 Tap Function Menu > Settings > Grid Parameters to access the parameters setting screen.
Figure 7-2 Grid parameters (advanced user)
----End
Parameter List
No.
Parameter
1
Grid code
2
Isolation
Issue 02 (2017-07-30)
The app screenshots in this chapter are for the SUN2000-60KTL-HV-D1-001. The
SUN2000 app version is V200R001C20SPC010.
Configurable parameters vary with the device model and grid code. The actual screen
prevails. The parameter list provided in this section includes all configurable parameters.
The parameter names, value ranges, and default values are subject to change. The actual
display prevails.
Description
Set this parameter based on the
grid code of the country or
region where the SUN2000 is
used and the SUN2000
application scenario.
Specifies the working mode of
the SUN2000 according to the
grounding status at the DC side
and the connection status to the
grid.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Default Value
Value Range
The default
N/A
value varies with
the model. The
displayed value
prevails.
The default
Input grounded,
value varies with
with TF
the grid code.
Input ungrounded,
The displayed
without TF
value prevails.
Input ungrounded,
with TF
71

Advertisement

Table of Contents
loading

Table of Contents