Fit the scanner module over the back of the WORKABOUT PRO
replaces the back plate of the unit.
Fasten the module in place with the screws provided. Tighten the screws to
a torque of 3 lbs-in (3kgf-cm).
Slide the SW1401 power switch to the right to turn power back on, and
replace the end-cap, backplate and battery. Tighten the end-cap screws to a
torque of 3 lbs-in (3kgf-cm).
Figure 8.10 Scanner Module Installed In WORKABOUT PRO
8.1.6.1

Enabling The SE 1223HP Scanner

Simultaneously, press and hold down the <BLUE> <ENTER> and left
<SCAN> keys for a minimum of 6 seconds. A
displayed on the WORKABOUT PRO screen.
Type s to display the
displayed.
Type 2 and press <ENTER> to activate scanner type SE 1223HP.
At the
Command>
Windows Mobile 2003 SE.

8.1.7 Installing An SE 923HP Scanner

Warning:
Anti-static devices MUST BE USED during the installation of
this scanner module. If unavailable, discharge static from your
body by touching a grounded metallic object before opening any
covers on the unit.