If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are
transmitted with one of the following prefixes:
]C1
if the first codeword is 903-907, 912, 914, 915
]C2
if the first codeword is 908 or 909
]C0
if the first codeword is 910 or 911
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted
with one of the following prefixes:
]L3
if the first codeword is 903-907, 912, 914, 915
]L4
if the first codeword is 908 or 909
]L5
if the first codeword is 910 or 911
Field Size/Char
Refer to page 117 for details.
6.20.1.17 2D RSS Code
Enable
Setting this parameter to on enables "2D RSS Code" scanning capability.
(Reduced Space Symbology)
Enable RSS-14
RSS-14 code can be either purely linear or split in half with one half stacked on top
of the other half. Stacking the code reduces the bar code length, and providing the
nominal height of the code is maintained, it can be omni-directionally scanned.
Enable RSS Limited
'RSS-Limited" is restricted, in that it can only encode 14 digit GTINs (global trade
item number) that begin with either a 0 or a 1. It is not stackable and is not designed
to be read omni-directionally.
Enable RSS Expanded
'RSS Expanded" uses the same application identifiers as UCC/EAN-128 codes but
it can be split into sections and stacked several rows high, reducing the length of the
symbol, while increasing the capacity of data that can be stored. "RSS Expanded"
code can be omni-directionally scanned