Description of the DESKLINE
DL1A system
®
Each DESKLINE
DL1A actuator is equipped with a motor and parallel/memory drive is ensured by means of software in the
®
CBD4/CBD5/CBD6 that also takes account of oblique load on the desk. Soft start and stop are also part of this software, which
ensures a soft start and stop when adjusting the desk.
The DESKLINE
DL1A system range contains the following products:
®
• 1 control box CBD4/CBD5/CBD6
• 1 single DL1A or 2, 3, or 4 parallel
• 1 exchangeable mains cable
• 1, 2, 3, or 4 motor cables
• 1 DP1U/DPF1M (if memory function is required) DP1C/WDPL/DPT/DPF1C (if memory function and display is required) or 1
DPA/DPB/DP1K/DP1V/DPF1K (if only up/down is required.)
Options:
•
Possibility of running extra actuators (LA31 with hall)
Application of the DESKLINE
DL1A system:
®
Irrespective of the load the duty cycle 10% ~ 6 min./ hour or max. 2 min. at continuous use stated in the data sheets,
must NOT be exceeded as this will result in a superheating of the motor, the brake and the spindle nut. Exceeding the duty
cycle will result in a dramatic reduction of the life of the system.
Maximum load for each DL1A: 1600 N
Maximum load for a system with CBD4 400 W: 3200 N
Maximum load for a system with CBD4 600 W: 4800 N
Maximum load for a system with CBD5 500 W: 3200 N
Maximum load for a system with CBD6 375 W: 2400 N