Cover Plate Assembly Only - Emerson HIGHPOINT CF205GES01 Owner's Manual

54” ceiling fan, brushed steel housing, dark mahogany, finish blades & opal matte glass
Table of Contents

Advertisement

WARNING
!
Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the
main fuse box before wiring. All wiring must be in
accordance with National and Local codes and the ceiling
fan must be properly grounded as a precaution against
possible electrical shock.
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
8.1
Detach the light kit plate from the fan motor/housing
assembly by removing one screw and loosening the two
other screws (located in the keyholes). Rotate the light kit
plate counter-clockwise to disengaging the screws in the
two key hole slots (Figure 31).
8.2
Disconnect the black wire of the light kit plate from the
black wire of the fan motor/housing assembly. Disconnect
the white wire of the light kit plate from the white wire of
the fan motor/housing assembly (Figure 32).
8. Disassemble Your Light Kit
for Cover Plate Assembly Only
FAN MOTOR/
HOUSING
ASSEMBLY
BLUE WIRE
BLACK WIRE
LIGHT KIT PLATE
Figure 31
LIGHT KIT
PLATE
CUT LIGHT
SOCKET WIRES
Figure 32
20
WHITE
WIRES
CUT LIGHT
SOCKET
WIRES
U.L. Model No.: CF205