Emerson CARRERA GRANDE CF787 series Owner's Manual

Emerson CARRERA GRANDE CF787 series Owner's Manual

Damp location ceiling fan

Advertisement

READ AND SAVE THESE INSTRUCTIONS
CARRERA GRANDE
Ceiling Fan Owner's Manual
CF787AW01 -
CF787AP01 -
CF787BS01 -
CF787CK01 -
CF787GBZ01 -
CF787GES01 -
CF787ORB01 -
CF787VNB01 -
Net Weight:
Part No. F40BP73770005
Damp Location
Model Numbers
Summer White
Antique Pewter
Brushed Steel
Chalk
25.3
Lbs.
Gilded Bronze
Golden Espresso
Oil Rubbed Bronze
Venetian Bronze
54", 60" or 72" Fan Blades
Not Included
Form No. BP7377-5
U.L. Model No.: CF787

Advertisement

Table of Contents
loading

Summary of Contents for Emerson CARRERA GRANDE CF787 series

  • Page 1 READ AND SAVE THESE INSTRUCTIONS CARRERA GRANDE ™ Damp Location Ceiling Fan Owner's Manual Model Numbers CF787AW01 - Summer White CF787AP01 - Antique Pewter CF787BS01 - Brushed Steel CF787CK01 - Chalk CF787GBZ01 - Gilded Bronze CF787GES01 - Golden Espresso CF787ORB01 - Oil Rubbed Bronze CF787VNB01 - Venetian Bronze...
  • Page 2: Safety Instructions

    WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control, Model No. SW46/UL Model No. UDC9020 manufactured by Rhine Electric Co., Ltd. WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
  • Page 3: Unpacking Instructions

    Emerson Electric Co. could result in personal The upper foam pad serves as a holder for the fan injury or property damage.
  • Page 4: Electrical Requirements

    Electrical Requirements Your new ceiling fan will require a grounded electrical WARNING supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and Turning off wall switch is not sufficient. To avoid capable of withstanding a load of at least 50 pounds.
  • Page 5 4. The blade flanges have an interlocking feature that 6. Position the switch housing assembly on the must be fully engaged before tightening the screw. switch housing plate and align the holes in the Make sure all the flanges are properly engaged switch housing assembly with the holes in the and then tighten the flange screws.
  • Page 6 11. Reinstall the hanger ball (Figure 9) on the NOTE: The setscrews must be properly installed as described above, or fan wobble could result. downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align WARNING the hanger ball so the pin is captured in the...
  • Page 7: How To Hang Your Ceiling Fan

    How to Hang Your Ceiling Fan 2. Carefully lift the fan and seat the hanger WARNING ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 12). Be The fan must be hung with at least 7' of clearance sure the groove in the ball is lined up with tab on from floor to blades (Figure 10).
  • Page 8: How To Wire Your Ceiling Fan

    OMITTED FOR CLARITY. ceiling. Figure 13 NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 13).
  • Page 9 6. If present, connect the supply white neutral wire to How to Wire Your the branch circuit white neutral wire with a wire Ceiling Fan - 4-Speed connector. Slide Wall Control WARNING This control is designed to operate only one ceiling Check to see that all connections are tight, including fan.
  • Page 10: Using Your Ceiling Fan

    Reverse Switch Information Emerson Electric Co. Substitution of parts or Season Rotation Direction Switch Position accessories not designated for use with this product by Emerson Electric Co. could result in personal Summer Counter-Clockwise Right injury or property damage. Winter Clockwise...
  • Page 11: Energy Efficient Use Of Ceiling Fans

    8 - 9 feet above the floor for optimal into the occupied space. Remember to adjust your airflow. Consult your Emerson Retailer for optional thermostat when using your ceiling fan - additional mounting accessories. energy and dollar savings could be realized with this simple step! Turn Off When Not in the Room.
  • Page 12: How To Order Repair Parts

    Repair Parts Listing Model Numbers Description CF787AW01 CF787BS01 CF787GBZ01 CF787GES01 CF787ORB01 CF787AP01 CF787VNB01 CF787CK01 Hanger Ball Assembly, 761655-21 761655-17 761655-77 761655-35 761655-32 761655-34 761655-89 761655-23 Consisting of: Hanger Bracket — — — — — — — — Hanger Ball — —...
  • Page 13: Repair Parts

    Repair Parts BLADES SOLD SEPARATELY U.L. Model No.: CF787...
  • Page 14: Trouble Shooting

    WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit 1.
  • Page 15 You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
  • Page 16 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73770005 Printed in China 10/11 Form No. BP7377-5 U.L. Model No.: CF787...

Table of Contents