Maintenance - Emerson HIGHPOINT CF205GES01 Owner's Manual

54” ceiling fan, brushed steel housing, dark mahogany, finish blades & opal matte glass
Table of Contents

Advertisement

IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to
avoid scratching the finish.
Abrasive cleaning agents are not required and should be
avoided to prevent damage to finish.
FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or circuit breaker blown.
2. Reversing switch in neutral position.
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Loose screws in motor housing.
3. Screws securing fan blade flanges to
motor hub are loose.
4. Screws holding blades to flanges
are loose.
3. Fan wobbles
1. Setscrews in motor coupler are loose.
excessively.
2. Setscrew in hanger ball/downrod
assembly is loose.
3. Screws securing fan blade flanges to
motor are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet
box is not securely fastened.
6. Fan blades out of balance.

13. Maintenance

Do not use water when cleaning your ceiling fan.
It could damage the motor or the blades and create the
possibility of an electrical shock.
14. Troubleshooting
WARNING
!
PROBABLE CAUSE
28
WARNING
!
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
WARNING
!
Make sure main power is turned OFF.
2. Make sure reversing switch position is all the way to
one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure the screws which attach
the fan flanges to the motor hub are tight.
4. Tighten screws securely.
1. Tighten both setscrews securely in the motor coupler.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan
blade flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat
firmly and uniformly to the surface of the motor.
If flanges are seated incorrectly, loosen the
flange screws and retighten according to the
procedure in the section on "Ceiling Fan Assembly".
5. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
U.L. Model No.: CF205