4.2.6.3 Select the Startup Pointer

Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
k
BASLER A102
The Startup Pointer is used to tag the configuration set that will be copied into the Work Set
at power on (see Section 3.11).
The write command is used to set the Startup Pointer to the Factory Set or to one of the User
Sets.
The read command returns the Set ID for the current setting.
This is a read or write command.
Cmd-ID
0x47
Cmd-ID
0x47
Cmd-ID
0x47
None
Byte 1
Set ID
Set
0x00
Factory Set
0x01
User Set 1
0x02
User Set 2
0x03
User Set 3
0x04
User Set 4
0x05
User Set 5
0x06
User Set 6
0x07
User Set 7
0x08
User Set 8
0x09
User Set 9
0x0A
User Set 10
0x0B
User Set 11
0x0C
User Set 12
0x0D
User Set 13
0x0E
User Set 14
0x0F
User Set 15
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
An ID that specifies the set.
(see the table below).