Query Commands - Basler A102K User Manual

Hide thumbs Also See for A102K:
Table of Contents

Advertisement

4.2.5 Query Commands

4.2.5.1 Read Vendor Information
Purpose:
Type:
Read Command:
Response:
Data Format:
4.2.5.2 Read Model Information
Purpose:
Type:
Read Command:
Response:
Data Format:
4.2.5.3 Read Product ID
Purpose:
Type:
Read Command:
Response:
Data Format:
k
BASLER A102
To read the camera vendor's name.
This is a read only command.
Cmd-ID
0x01
Cmd-ID
0x01
Zero terminated string if less than 16 bytes are needed for the vendor
information. Unterminated string if all 16 bytes are needed.
To read the camera's model number.
This is a read only command.
Cmd-ID
0x02
Cmd-ID
0x02
Zero terminated string if less than 16 bytes are needed for the model
information. Unterminated string if all 16 bytes are needed.
To read the camera's product ID number.
This is a read only command.
Cmd-ID
0x03
Cmd-ID
0x03
Zero terminated string if less than 16 bytes are needed for the product ID
information. Unterminated string if all 16 bytes are needed.
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
Configuring the Camera
Data
16
-
Data
16
16 Bytes
Data
16
-
Data
16
16 Bytes
Data
16
-
Data
16
16 Bytes
4-19