Configuring the Camera

4.2.4.6 Area of Interest Starting Column

Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4.2.4.7 Area of Interest Width in Columns
Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4-14
To set the starting column for the area of interest or to read the current setting. See Section
3.8 for details on the area of interest.
This is a read or write command.
Cmd-ID
0xA9
Cmd-ID
0xA9
Cmd-ID
0xA9
None
Byte 1
Byte 2
The starting column setting can range from 0 (0x0000) to 1391 (0x056F).
When you set column n using this command, the actual starting column will
be n + 1. For example, if you set the starting column to 0 with this command,
the actual starting column = 0 + 1 = 1.
To set the width in columns for the area of interest or to read the current setting. See
Section 3.8 for details on the area of interest.
This is a read or write command.
Cmd-ID
0xAB
Cmd-ID
0xAB
Cmd-ID
0xAB
None
Byte 1
Byte 2
The width in columns setting can range from 1 (0x0001) to 1392 (0x0570).
See Section 3.8.1 for a list of guidelines which must be followed when entering the
settings for the area of interest.
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of the starting column setting
High byte of the starting column setting
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of the width in columns setting
High byte of the width in columns setting
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
BASLER A102