Area Of Interest Starting Line - Basler A102K User Manual

Hide thumbs Also See for A102K:
Table of Contents

Advertisement

4.2.4.8 Area of Interest Starting Line

Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4.2.4.9 Area of Interest Height in Lines
Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
k
BASLER A102
To set the starting line for the area of interest or to read the current setting. See Section 3.8
for details on the area of interest.
This is a read or write command.
Cmd-ID
0xA8
Cmd-ID
0xA8
Cmd-ID
0xA8
None
Byte 1
Byte 2
The starting line setting can range from 0 (0x0000) to 1039 (0x040F).
When you set line n using this command, the actual starting line will be
n + 1. For example, if you set the starting line to 0 with this command, the
actual starting line = 0 + 1 = 1.
To set the height in lines for the area of interest or to read the current setting. See Section
3.8 for details on the area of interest.
This is a read or write command.
Cmd-ID
0xAA
Cmd-ID
0xAA
Cmd-ID
0xAA
None
Byte 1
Byte 2
The height in lines setting can range from 1 (0x0001) to 1040 (0x0410).
See Section 3.8.1 or a list of guidelines which must be followed when entering the
settings for the area of interest.
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of the starting line setting
High byte of the starting line setting
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of the height in lines setting
High byte of the height in lines setting
Configuring the Camera
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
4-15