Configuring the Camera

4.2.4.10 Gain

Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4.2.4.11 Offset
Purpose:
Type:
Read Command:
Response:
Write Command:
Response:
Data Format:
Data Range:
4-16
To set the gain or to read the current gain setting. See Section 3.6 for more information on
gain.
This is a read or write command.
Cmd-ID
0x80
Cmd-ID
0x80
Cmd-ID
0x80
None
Byte 1
Byte 2
Gain settings can range from 0 (0x0000) to 1023 (0x03FF). The minimum
recommended setting is 240 (0x00F0) with vertical binning disabled or 192
(0x00C0) with vertical binning enabled. See Section 3.6.1.
To set the offset or to read the current offset setting. See Section 3.6 for more information
on offset.
This is a read or write command.
Cmd-ID
0x84
Cmd-ID
0x84
Cmd-ID
0x84
None
Byte 1
Byte 2
Offset settings can range from 0 (0x0000) to 255 (0x00FF).
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of gain setting
High byte of gain setting
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
R/W-Flag
Data Length
0
Low byte of offset setting
High byte of offset setting
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
Data
2
-
Data
2
2 Bytes
Data
2
2 Bytes
BASLER A102