Configuring the Camera

4.2.5.9 Read Minimum Gain Setting

Purpose:
Type:
Read Command:
Response:
Data Format:
4-22
To read the minimum gain setting for standard operation (vertical binning disabled)
(see Section 3.6.1).
This is a read only command.
Cmd-ID
0x08
Cmd-ID
0x08
Byte 1
Byte 2
Bytes 3 to 16
DRAFT
R/W-Flag
Data Length
1
R/W-Flag
Data Length
0
Low byte of minimum gain setting.
High byte of minimum gain setting.
Reserved. Should be ignored.
Data
16
-
Data
16
16 Bytes