Functional Description - Basler A102K User Manual

Hide thumbs Also See for A102K:
Table of Contents

Advertisement

3 Basic Operation and Features

3.1 Functional Description

The A102
area scan camera employs a CCD-sensor chip which provides features such as
k
electronic exposure time control and anti-blooming. Exposure time is normally controlled via an
externally generated sync signal (ExSync). The ExSync signal facilitates periodic or non-periodic
pixel readout.
When exposure is controlled by an ExSync signal, exposure time can be either level-controlled or
programmable. In level-controlled mode, charge is accumulated when the ExSync signal is low
and a rising edge of ExSync triggers the readout of accumulated charges. In programmable mode,
exposure time can be programmed to a predetermined time period. In this case, exposure begins
on the rising edge of ExSync and accumulated charges are read out when the programmed
exposure time ends.
A free-run mode that allows the camera to operate without an ExSync signal is also available. In
free-run mode, the camera generates its own internal control signal and the internal signal is used
to control exposure and charge read out. When operating in free-run, the camera outputs frames
continuously.
At readout, accumulated charges are transported from the light-sensitive sensor elements (pixels)
to the CCD vertical shift registers. The charges from the bottom line of pixels in the CCD array are
then moved into a horizontal shift register as shown in Figure 3-1. The horizontal register shifts
out charges from left to right, that is, pixel 1, pixel 2, pixel 3, and so on.
As charges move out of the horizontal shift register, they are converted to voltages proportional
to the size of each charge. Shifting is clocked according to the camera's 28 MHz internal data rate.
The voltages moving out of the shift register are amplified by an internal Variable Gain Control
(VGC) and then digitized by a 12 bit, Analog-to-Digital converter (ADC). Once the pixels are
digitized, they will be transmitted out of the camera in ascending numerical order from pixel 1
through pixel 1392. All lines are read out in a single frame (progressive scan).
The digitized video data is transmitted from the camera to the frame grabber using a format
compatible with the Camera Link standard. Lines are output sequentially in a progressive scan
until one full frame is obtained.
For optimal digitization, gain and offset are programmable via a serial port.
k
BASLER A102
DRAFT
Operation and Features
3-1

Advertisement

Table of Contents
loading