Assembling

4.8 Mounting power supply units

4.8
Mounting power supply units
4.8.1
19" rack mounting of the PS598-1 power supply unit
Notes on 19" rack mounting of the PS598-1 power supply unit
The PS598-1 was developed specifically for use with the SCALANCE XR528-6M and
SCALANCE XR552-12M devices. This power supply unit can be mounted directly above or
below a SCALANCE XR-500 since the ventilation slits are on the sides of both the basic
device and the power supply unit.
Risk of injury if subjected to irregular mechanical strain
The device must be mounted in the rack so that even if there is irregular mechanical strain,
no dangerous situation can result.
Procedure
Figure 4-4
To mount the PS598-1 power supply unit in a 19" rack, follow the steps below:
1. Secure the two mounting brackets with four screws each (M3 x 6 supplied with the
2. Screw the PS598-1 power supply unit to the 19" rack
42
CAUTION
19" rack mounting of the power supply unit
product) to the side panels of the power supply unit
The maximum tightening torque for these screws is 0.5 Nm.
.
.
Operating Instructions, 05/2014, A5E03275845-05