Mechanical Stability (In Operation) - Siemens SCALANCE XR524-8C Operating Instructions Manual

Simatic net scalance xr-500 series industrial ethernet switches
Hide thumbs Also See for SCALANCE XR524-8C:
Table of Contents

Advertisement

Certification

10.2 Mechanical stability (in operation)

10.2
Mechanical stability (in operation)
Device
SCALANCE XR524-8C
SCALANCE XR528-6M
SCALANCE XR552-12M
" When rack mounted with four securing points
98
IEC 60068-2-6 vibration *
5 - 9 Hz: 3.5 mm
9 - 150 Hz: 1 g
1 octave/min, 20 sweeps
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
Operating Instructions, 05/2014, A5E03275845-05
IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
SCALANCE XR-500