Siemens SCALANCE XR524-8C Operating Instructions Manual page 17

Simatic net scalance xr-500 series industrial ethernet switches
Hide thumbs Also See for SCALANCE XR524-8C:
Table of Contents

Advertisement

Restart with the SELECT/SET button disabled for "Restore Factory Defaults"
If you have disabled the SELECT/SET button for "Restore Factory Defaults" in the
configuration, this does not apply during the startup phase. When you restart after cycling
power, the configuration can nevertheless be deleted using this button. This action cannot
be undone and you then need to reload the device configuration. This can lead to
disturbances and failures in the corresponding network area.
Defining the fault mask
Using the fault mask, you specify an individual "good status" for the connected ports and the
power supply. Deviations from this status are displayed as errors/faults.
To define the fault mask, follow the steps below:
1. Change to display mode D.
2. Hold down the "SELECT/SET" button for 5 seconds.
Enabling/disabling the redundancy manager
To enable/disable the redundancy manager, follow the steps below:
1. Change to display mode B.
2. Hold down the "SELECT/SET" button for 5 seconds.
SCALANCE XR-500
Operating Instructions, 05/2014, A5E03275845-05
CAUTION
Display mode D is active when the "DM1" and "DM2" LEDs are lit green.
If a different display mode is active, press the "SET/SELECT" button several times briefly,
until the "DM1" and "DM2" LEDs are lit green.
After 2 seconds, the "DM1" and "DM2" LEDs start to flash for 3 seconds. At the same
time the port LEDs go on one after the other.
After you have pressed the button for 5 seconds, the current settings are stored as the
"good status".
If you release the button before the 5 seconds are up, the previous fault mask is retained.
Display mode B is active when the "DM1" LED is lit green and the and "DM2" LED is off.
If a different display mode is active, press the "SET/SELECT" button several times briefly,
until the "DM1" LED is lit green and the "DM2" LED is off.
After 2 seconds, the "DM1", "DM2" and "RM" LEDs start to flash for 3 seconds. At the
same time, the port LEDs light up one after the other.
If you release the button before the 5 seconds have elapsed, the action is canceled.
The result of the action depends on the initial situation:
– Initial situation:
The redundancy manager and media redundancy are disabled.
Result:
After enabling the redundancy manager, media redundancy is also enabled.
– Initial situation:
The redundancy manager and media redundancy are enabled.
Result:
After disabling the redundancy manager, media redundancy remains enabled.