Siemens SCALANCE XR524-8C Operating Instructions Manual page 21

Simatic net scalance xr-500 series industrial ethernet switches
Hide thumbs Also See for SCALANCE XR524-8C:
Table of Contents

Advertisement

Meaning in display mode D
In display mode D, the "L1" and "L2" LEDs indicate whether the power supply is monitored.
Table 3- 3
LED color
-
Green
Table 3- 4
LED color
-
Green
SCALANCE XR-500
Operating Instructions, 05/2014, A5E03275845-05
Monitoring for devices with 24 VDC
L1/L2 LED
L1/L2 connector
LED status
Off
Power supply is not monitored.
If the power supply falls below 17 VDC, the signaling contact does
not respond.
On
Power supply is monitored.
If the power supply falls below 17 VDC, the signaling contact
responds.
Monitoring for devices with 100 to 240 VAC
L1/L2 LED
L1/L2 connector
LED status
Off
Power supply is not monitored.
If the power supply falls below 90 VAC, the signaling contact does
not respond.
On
Power supply is monitored.
If the power supply falls below 90 VAC, the signaling contact
responds.
Description of the device
3.3 LED display
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr552-12mScalance xr528-6m

Table of Contents