3.5

Combo ports

The following devices have combo ports:
● SCALANCE XR524-8C
Characteristics
Combo port is the name for two communication ports. A combo port has the two following
jacks:
● a fixed RJ-45 port
● an SFP transceiver slot that can be equipped individually
Of these two ports, only one can ever be active. Using the mode, you can decide how the
ports are prioritized.
The port name is the same on both jacks of the combo port, for example "P3C.
For each combo port there is an LED. The LEDs for the combo ports can be identified by a
vertical line and the word "COMBO". The labeling of the combo port LEDs does not differ
from that of the other LEDs, e.g. "P3".
Setting the mode
The following modes can be configured for a combo port:
● Mode 1: auto
● Mode 2: rj45
● Mode 3: sfp
The factory setting for the combo ports is mode 1: auto.
You configure the mode with Web Based Management or the Command Line Interface.
SCALANCE XR-500
Operating Instructions, 05/2014, A5E03275845-05
The SFP transceiver port has priority. As soon as an SFP transceiver is plugged in, an
existing connection at the fixed RJ-45 port is terminated. If no SFC transceiver is plugged
in, a connection can be established via the fixed RJ-45 port.
The fixed RJ-45 port is independent of the SFP transceiver port.
The pluggable transceiver port is used independent of the fixed RJ-45 port.
Description of the device
3.5 Combo ports
27