Capabilities - Ericsson CME 20 R6.1 Reference Manual

Table of Contents

Advertisement

EMC Capabilities for RBS 2301
39.3

Capabilities

39.3.1
RBS Description
Hardware
The capabilities are tested for an RBS equipped with a minimum
representative configuration of units. This system is representative of
installed systems in terms of function, which includes at least one of
each function unit type, and electromagnetic radiation characteristics.
The number and types of sub-units are given from results of
investigations in accordance with ETS 300 342-2, Nov 1994.
Software
The capabilities are valid for a standard setup of system software with
default parameters.
Performance
For the immunity capabilities the RBS is operating and will fulfil the
performance criteria stated for each test.
For emission capabilities all equipment in the RBS was enabled during
verification to create the worst emission case.
EMC directive
The EMC capabilities of the RBS fulfills the mandatory requirements
specified in the EMC directive, 89/336/EEC, which gives compliance
for trade in EU member countries.
Generic Standards
The following generic standards are fulfilled by the system:
EN 50 081–1, Jan 1992 Emission
EN 50 082–1, Jan 1992 Immunity
39.3.2
Conducted Emission
Table 28
Basic standard
Limit
Table 29
Basic standard
Limit
Table 30
Basic standard
Limit
258 (306)
Voltage fluctuation on AC power supply leads
IEC 1000-3-3
Set by Table II in IEC 1000-3-3
Harmonics on AC power supply leads
IEC 1000-3-2
Set by Table 1 in IEC 1000-3-2
Interference on AC power supply leads
EN 55 022
Class B
© Ericsson Radio Systems AB
— All Rights Reserved —
EN/LZT 123 2697
R5A
1998-08-13