Functionality Administration - Ericsson CME 20 R6.1 Reference Manual

Table of Contents

Advertisement

23

Functionality Administration

"Functionality Administration" provides the functionality necessary to
allow the BSC to configure, enable and disable AOs within the RBS.
This function also includes general layer 3 A-bis OML support for other
functions within the RBS.
23.1
Concepts
Application Object
Elementary Procedure
Managed Object
EN/LZT 123 2697
R5A
1998-08-13
An abstract subclass of MO, which
provides part of the functionality of a BTS
The protocol over the A-bis OML at layer
3 consists of EPs (Elementary
Procedures). An EP is a unit of interaction
between the BSC and one of the MOs. An
EP consists of an initiating message and a
response. For example, an EP may consist
of the BSC sending an initiating message
CONFIGURE REQUEST and the MO in
the RBS responding with a message
CONFIGURE REQUEST ACK.
The BSC manages the O&M of the RBS
via the A-bis O&M Interface. The RBS
equipment is seen as MOs by the BSC.
This is a means of describing the RBS in a
function-oriented way, and a logical model
of the RBS in terms of MOs is built in the
BSC. All O&M actions are based on this
logical model structure created in the BSC.
An MO does not necessarily have a one-
to-one relation with a physical unit in the
RBS, and the MO comprises both
hardware and software.