CMRU
33.3

Functions

33.3.1
DS1 Transmission
The function is initiated during restart of CMRU.
The function can be in one of the following two modes:
The functionality described under the heading Basic is common for both
short and long haul.
Basic
EN/LZT 123 2697
R5A
1998-08-13
Transmission Interface Handling DS1 1544 kbit/s
Transport network
BSC
Two RBSs in a linear cascade chain
Short haul
Long haul
Physical and electrical characteristics according to ANSI T1.403
(interface at 1544 kbit/s, one pair for each direction of
transmission, test load impedance 100
© Ericsson Radio Systems AB
— All Rights Reserved —
The path for information from the BSC to
the MS.
The path for information from the MS to
the BSC.
A cascade of RBS:s according to Figure
40 on page 201.
RBS 1
DXB
PCM-A
PCM-B
RBS 2
DXB
PCM-A
PCM-B
Central Main Replaceable Unit. An RBS
has exactly one CMRU. In the RBS 2000
hardware architecture the Distribution
Switch is the CMRU.
, resistive).
01_0428A
201 (306)