17.4

Operational Conditions

The diversity supervision is characterised by a number of parameters
which are implemented as software constants. The parameter values are
selected so that the risk of false disturbances during normal operation is
negligible:
Table 15
Observation period
Channel utilisation threshold
Minimum channel utilisation ratio
Disturbance threshold
The disturbance filter characteristics will give the time to alarm. If
100% of the observation periods causes a disturbance, the time to alarm
will be 50 minutes. If the disturbance ratio is less than 50% no alarm
will be raised.
If 100% of the observation periods indicates no disturbance, the alarm
will be terminated after 100 minutes. If the disturbance ratio is more
than 15%, the alarm will not be terminated.
EN/LZT 123 2697
R5A
1998-08-13
Preliminary diversity supervision parameters
© Ericsson Radio Systems AB
— All Rights Reserved —
Diversity Supervision
5 minutes
-96 dBm
5 %
12 dB
123 (306)