Cleaning the Syrup Connections

Syrup connections should be cleaned at least every six months, or when syrup types are changed. Perform the
procedure in Table 39 to clean the BIB connectors.
Step
1.
2.
3.
4.
Servicing Motorman Dispensing Valves
NOTE: Dispensing valves with caged o-rings should be serviced (lubricated) every six months and o-rings
should be replaced once a year.
Refer to Figure 33 and perform the procedure in Table 40 to lubricate or change the caged o-rings in each dispens-
ing valve on the unit.
© 2016, Cornelius Inc
Re-install the faceplate and replace the four (4) mounting nuts. Hand tighten
the nuts until the faceplate makes contact with the gasket, then use a wrench
to tighten the nuts an additional 1/4 turn. Be careful not to over tighten the nuts
or cracking of the faceplate may result.
Refill the barrel with product. See "Filling a Barrel" on page 25.
When barrel fill is complete, perform a motor calibration. See "Calibrating a
Motor" on page 32.
Open the merchandiser and select OFF for the barrel to be cleaned.
Remove the quick disconnect from the BIB container.
Fill a suitable pail or bucket with soap solution.
Submerge the disconnect in the soap solution and then clean it using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water and dry.
Figure 33. Self-Closing Dispensing Valve