Note 1) Please note that the version is subject to change.
Note 2) Each file can be downloaded from SMC website (http://www.smcworld.com).
Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
SI Unit Dimensions/Parts Description
EX140-SMJ1, SCS, SSL, SUW1, SUH1
Position indicator LED
94.5
EX140-SDN1
EX140-SMJ1
DeviceNet™
CC-Link
Release 2.0
Ver. 1.10
156 k/625 kbps
125 k/250 k/500 kbps
2.5 M/5 M/10 Mbps
EDS file
32/32
0/16
(1 station, remote
I/O stations)
11 to 25 VDC
15 to 30 VDC
24 VDC+10%/–5%
16 outputs
Solenoid valve with surge voltage suppressor 24 VDC, 2.1 W or less (SMC)
1500 VAC for 1 min. between whole external terminal and enclosure
2 MΩ or more (500 VDC) between whole external terminal and enclosure