EX180-TFO09
Installation & Maintenance Manual
Fieldbus system - SI unit
TM
Type EX180 Series for DeviceNet
EX180-SDN3 /SDN4 /SDN5 /SDN6
Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of
"Caution", "Warning" or "Danger". They are all important notes for safety
and must be followed in addition to International standards (ISO/IEC)
and other safety regulations.
CAUTION indicates a hazard with a low level of risk
Caution
which, if not avoided, could result in minor or
moderate injury.
WARNING indicates a hazard with a medium level
Warning
of risk which, if not avoided, could result in death or
serious injury.
DANGER indicates a hazard with a high level of risk
Danger
which, if not avoided, will result in death or serious
injury.
This product is class A equipment that is intended for use in an industrial
environment.
There may be potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted as well as radiated
disturbances.
Warning
Do not disassemble, modify (including changing the printed
circuit board) or repair.
An injury or failure can result.
Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids.
Fire, malfunction, or damage to the product can result.
Verify the specifications before use.
Do not operate in an atmosphere containing flammable or
explosive gases.
Fire or an explosion can result.
This product is not designed to be explosion proof.
If using the product in an interlocking circuit:
•Provide a double interlocking system, for example a mechanical
system.
•Check the product regularly for proper operation.
Otherwise malfunction can result, causing an accident.
The following instructions must be followed during maintenance:
•Turn off the power supply.
•Stop the air supply, exhaust the residual pressure and verify that the
air is released before performing maintenance.
Otherwise an injury can result.
Caution
After maintenance is complete, perform appropriate functional
inspections.
Stop operation if the equipment does not function properly.
Safety cannot be assured in the case of unexpected malfunction.
Provide grounding to assure the safety and noise resistance of
the Fieldbus system.
Individual grounding should be provided close to the product with a
short cable.
NOTE
When conformity to UL is necessary the SI unit must be used with a UL
1310 Class2 power supply.
Summary of Product Parts
<EX180-SDN3 /SDN4 /SDN5 /SDN6 >
4
5
1
3
2
<Accessories>
Communication connector for DeviceNet
(1 pc.)
Power supply
TM
EX180-SDN3/4/5/6
EX180-SDN3A/4A/5A/6A
connector (1 pcs.)
6
6
(EX180-CDN1)
(EX180-CDN2)
(EX180-CP1)
No.
Item
Description
The connector for the DeviceNet
TM
Fieldbus interface
1
6
(
).
connector (BUS)
The connector for the power supply (
Power supply
2
used to supply the power for the solenoid
connector (PWR(V))
valves.
3
FG terminal
Functional Earth.
4
Display
LED diagnostic display.
Switches to set the MAC ID and
5
Setting switches
communication speed (inside the cover).
Installation
General Instructions on Installation
Applicable valve series
The EX180 series SI unit can be mounted on the following valve
manifolds.
SJ2000/3000, S0700 series
: Refer to the catalogues and operation manuals for details of the solenoid
valves and manifolds.
•How to mount the manifold
1. Mount the SI unit to the manifold so that the mounting guide of the
SI unit case mates with the manifold groove.
2. Secure the SI unit using the two sliding locks.
1
7
Wiring
1. Wiring for communication
bus line
Wiring of the DeviceNet
communication cable and connector is
TM
shown below.
7
)
(1)Connect the signal wires to the assigned pins. (Figure 1)
The required tightening torque is 0.5 to 0.6 Nm.
V+ CAN_H Drain CAN_L V-
Red
White Drain Blue Black
Figure 1
(2)A bus termination is required at both ends of the DeviceNet
segment as shown in Figure 2.
The specification of the terminating resistor is 121 Ω ±1%, 1/4 W.
V+ CAN_H Drain CAN_L V-
Red
White Drain
Blue Black
Terminating resistor
Figure 2
Installation (Continued)
(3)How to connect.
Communication connector
for DeviceNet
2
2. Wiring of the power supply
Connect the power supply to the power supply connector (1 pc.).
The EX180 power supply structure consists of two supplies.
These supplies can be operated using a single or dual power supply
system.
Connect the wires to the assigned pins. (Figure 4, Figure 5)
The required tightening torque is 0.22 to 0.25 Nm.
•Note
Connect the FG terminal to ground with a ground resistance of
100 Ω or less.
Solenoid valve
power supply
24 VDC
Red
White Drain Blue Black
V+ CAN_H Drain CAN_L V-
bus
TM
Power supply connector
Red
White Drain Blue Black
V+ CAN_H Drain CAN_L V-
Terminating resistor
TM
Figure 3
A. Dual power supplies
DeviceNet
power supply
TM
24 VDC
B. Single power supply
24 VDC
Figure 4
Figure 5